Lecture 02 — From specification to implementation evidence

Course guide · Previous · Next: Lecture 03

The first design task is to write a contract precise enough that a wrong implementation can be rejected. Use the one-entry streaming incrementer as the running example. It accepts an unsigned byte, adds one with saturation at 255, and emits the result through a valid/ready interface. It has one storage slot. This small module exposes the same ordering and flow-control problems that appear at accelerator command and DMA boundaries.

Separate the stages

Stage What it establishes What it does not establish
Parse/elaborate The source and design hierarchy are accepted Correct output values or temporal behavior
Functional simulation Behavior matches the checker on exercised traces Exhaustive behavior, synthesis, or timing closure
Formal verification Stated properties hold under stated assumptions Properties omitted from the specification
Synthesis RTL maps to a selected logic representation Routed timing, actual board behavior, measured power
Physical implementation Placement/routing under specified constraints Correctness outside the constraints or silicon measurements

A result should name its stage. “Passed simulation with Icarus 12” is reviewable. “Chip verified” does not say what evidence exists. The provided lab has been simulated; this course review did not perform synthesis, place-and-route, or silicon validation.

Write the transfer rule before the datapath

At each active clock edge, an input is accepted only when s_valid && s_ready. An output is delivered only when m_valid && m_ready. If valid is high and ready is low, the producer must retain its value until a transfer or the specified reset behavior. The example masks handshakes during reset and clears its valid state on a reset clock edge; read the lab's precise reset convention.

The one-slot buffer can accept a replacement in the same cycle its old output is consumed. A useful readiness equation is empty || downstream_ready, subject to the reset rule. If full and downstream is stalled, accepting another input would overwrite an undelivered value.

Worked trace: accept 254 into an empty buffer; its stored result is 255. Stall the output for three cycles. Every stalled cycle must expose the same 255 with valid asserted. Then consume it while accepting 255; the replacement is also 255 because arithmetic saturates. On the next ready cycle, deliver that replacement. Two accepted items must produce two deliveries unless reset explicitly flushes one.

Execute the baseline

From the repository root, with Icarus Verilog installed:

python3 'Phase 4 - Track A - Xilinx FPGA/1. Xilinx FPGA Development/labs/run_stream_lab.py' --seed 1 --output /tmp/rtl-baseline.json

The report includes acceptance, delivery, flush, stall, replacement, and saturation counters. Read them alongside the testbench; a counter is meaningful only if its event definition matches the contract. Keep the seed and tool version with the report.

Exercise: an implementation emits the right values on a continuously ready interface, but changes output data while stalled. Which stage and test catch it? Answer: the directed stall test in functional simulation can reject it before synthesis. A no-backpressure test cannot establish this requirement.

Your deliverable is a one-page contract with ports, clock/reset behavior, numerical overflow rule, transfer rule, and a short expected trace. Then continue to Lecture 03 and give that contract to a generator.